Share:


OMNIA II® Electrical Safety Compliance Analyzer



Specifications

SKU: OMNIA II 8207

OMNIA II 8207 Electrical Safety Compliance Analyser

The OMNIA II 8207 Electrical Safety Compliance Analyser combines multiple electrical safety tests in one instrument for product evaluation and manufacturing checks.

Seven Tests In One Electrical Safety System

The 8207 integrates AC and DC dielectric withstand, insulation resistance, AC ground bond, ground continuity, touch/leakage current and functional run tests. Combining these functions supports laboratory evaluation and production-line test sequences for electrical products, including appliances and medical equipment where the selected methods apply.

Testing Workflow And Leakage Evaluation

DualCHEK permits simultaneous Hipot and ground bond testing. Hot Hipot capability supports testing a powered device. Built-in human-body simulation measuring networks support leakage assessments under selected conditions, while neutral, ground and polarity switching help reproduce fault arrangements. Choose test methods and limits from the applicable product standard.

Automation And Test Records

RS-232 and USB support system integration; GPIB and Ethernet are optional. Compatible WithStand desktop/cloud software is available for organising sequences and results, subject to the required software arrangement. An interlock connection, controlled discharge and suitable high-voltage accessories form part of a properly designed test setup.

Key Features

  • Seven electrical safety and functional test capabilities
  • AC and DC dielectric withstand testing
  • Ground bond, continuity and insulation resistance testing
  • Leakage current and functional run testing
  • DualCHEK simultaneous Hipot and ground bond testing
  • Hot Hipot testing of powered devices
  • Built-in measuring networks for leakage evaluation
  • Neutral, ground and polarity fault switching
  • Functional voltage, current, power and power-factor measurements

Technical Specifications

Specification Details
Model OMNIA II 8207
AC Hipot Output 0 to 5,000 VAC
AC Leakage Limit 0.001 to 50 mA
DC Hipot Output 0 to 6,000 VDC
Ground Bond Current 1 to 40 AAC
AC Hipot Frequency 50/60 Hz
DC Hipot Leakage Limit Up to 20 mA
Ground Bond Output Voltage 3 to 8 VAC
Ground Bond Resistance Range 0 to 600 mΩ at 1–10 A; 0 to 200 mΩ at 10.01–30 A; 0 to 150 mΩ at 30.01–40 A
Standalone Continuity Test Current 10 mA DC (±0.01 mA)
Continuity Resistance Range 0 to 10,000 Ω
Touch Current Measurement Up to 10 mA RMS or 100 mA peak; resolution and bandwidth depend on range
Run-Test Metering 0–277 VAC; 0–16 AAC; 0–4,500 W; power factor 0–1
Built-In AC Source 630 VA and 500 W maximum; 0–150 VAC at up to 4.20 A or 0–277 VAC at up to 2.10 A; 45–500 Hz
Insulation Resistance Test 30 to 6,000 VDC; 0.05 MΩ to 50 GΩ
Hipot Ground Continuity Fixed 100 mA DC (±10 mA); fixed resistance limit 1 Ω (±0.1 Ω)
Interfaces RS-232 and USB; optional GPIB and Ethernet


Applications

Electrical safety evaluation, manufacturing safety test stations, appliance testing and suitable medical electrical product test workflows.

Configuration And Selection Notes

These values apply to OMNIA II 8207. Its AC leakage limit is 50 mA, not the 100 mA quoted for certain other models. Test capability alone does not establish product certification. Standalone continuity uses 10 mA DC; the Hipot ground-continuity function uses a separate fixed 100 mA DC current. Ground bond resistance limits depend on test current. The run-test metering limits are measurement capabilities and do not increase the built-in AC source rating of 630 VA and 500 W maximum.


Contact us to enquire about the OMNIA II 8207 Electrical Safety Compliance Analyser and the configuration or accessories suited to your application.



 Inquiry - OMNIA II® Electrical Safety Compliance Analyzer