2

Share:


Fluke Calibration 9144 Metrology Well for Temperature Calibration



Specifications

SKU: FLUKE-9144

Fluke Calibration 9144 Metrology Well

The Fluke Calibration 9144 Metrology Well provides a controlled high-temperature source for calibrating temperature probes in laboratories and industrial facilities.

Calibrate Temperature Sensors And Complete Loops

The 9144 creates a physical temperature environment for PRTs, RTDs and thermocouples, allowing the sensor to be checked together with associated instrumentation. Suitable inserts provide the required fit and immersion. The high-temperature range is useful for industrial probe calibration and comparison measurements.

Stable Operation In The Field

The LCD, dedicated set-point control and visual/audible stability indications help operators determine when to take readings. Published performance addresses stability, axial and radial uniformity, loading and hysteresis, all of which matter when comparing several probes in the block.

Optional Process Readout And Test Documentation

The -P process version adds a reference PRT readout and a user-selectable measurement channel for RTDs, thermocouples or current signals, plus 24 V loop power. It can store up to 20 calibration tests with reference and instrument readings, errors, dates and times. Thermostatic switch testing supports automatic or manually configured sequences. The 1586A Super-DAQ can be used for automated sensor calibration.

Key Features

  • High-temperature dry-block calibration
  • Temperature stability suited to probe comparison
  • Portable design for bench and field use
  • Optional process configuration for additional measurement functions
  • Fast heating for high-temperature calibration work
  • RS-232 computer interface
  • User-selectable °C or °F display
  • Process readout and documentation available with the -P version

Technical Specifications

Specification Details
Model 9144
Temperature Range 50 to 660 °C at 23 °C ambient
Well Depth 150 mm
Weight 7.7 kg
Display Accuracy ±0.35 °C at 50 and 420 °C; ±0.5 °C at 660 °C
Stability ±0.03 °C at 50 °C; ±0.04 °C at 420 °C; ±0.05 °C at 660 °C
Radial Uniformity ±0.02 °C at 50 °C; ±0.05 °C at 420 °C; ±0.10 °C at 660 °C
Heating Time Approximately 15 minutes, 50 to 660 °C
Cooling Time Approximately 25 minutes, 660 to 100 °C
Display Resolution 0.01 °C or °F
Dimensions (H × W × D) 290 × 185 × 295 mm


Applications

Industrial temperature probe calibration, transmitter loop checks, thermocouple comparison and thermostatic switch testing.

Configuration And Selection Notes

The 9144 range is 50 to 660 °C at 23 °C ambient. The wider negative-temperature range quoted for the product family belongs to other models. Specifications other than the temperature range apply at an ambient temperature of 13 to 33 °C. Readout uncertainty and probe uncertainty are separate contributions.


Contact us to enquire about the Fluke Calibration 9144 Metrology Well and the configuration or accessories suited to your application.



 Inquiry - Fluke Calibration 9144 Metrology Well for Temperature Calibration