2

Share:


Fluke 754 Documenting Process Calibrator-HART



Specifications

SKU: FLUKE-754

Fluke 754 Documenting Process Calibrator With HART

The Fluke 754 Documenting Process Calibrator With HART combines process signal calibration and documentation to support instrument maintenance and verification.

Measure, Source And Simulate Process Signals

The 754 covers voltage, current, resistance, frequency, thermocouples and RTDs. It can source or simulate a signal while measuring the response, with a dual display for both values. Pressure measurement uses compatible 750P Series modules and an appropriate external pressure source where pressure generation is needed.

Calibration-Related HART Communication

The integrated HART interface supports compatible smart-transmitter calibration and maintenance tasks alongside analogue measurements. Use it for the supported device functions and calibration workflow. It should not be assumed to replace every commissioning or configuration function of a full HART communicator.

Documented Procedures And Automated Steps

Download procedures, instructions and instrument lists from compatible calibration management software and upload results for records. Programmable autostep, ramping, delays and switch testing help run repeatable checks. Data logging records selected measured functions, while DPCTrack2 integration is available for compatible paperless workflows.

Key Features

  • Measure, source and simulate process signals
  • Calibration-related HART communication
  • Store calibration procedures and results
  • Loop power capability for transmitter testing
  • Dual display for sourced and measured values
  • Programmable auto-step and ramp functions
  • One- or two-point switch testing
  • Supports compatible pulsed RTD transmitters and PLCs
  • Rechargeable battery and USB PC connection

Technical Specifications

Specification Details
Model 754
Communication HART for supported calibration tasks
Pressure Functions Require compatible external pressure modules
Maximum DC Voltage Measurement Range 300 V
Maximum DC Voltage Source Range 15 V
Maximum DC Current Measurement Range 110 mA
Current Source Range Up to 22 mA
Frequency Coverage Measurement and source functions up to 50 kHz; settings depend on function
Data Logging Capacity Up to 8,000 readings; 7,980 at selected higher logging rates
Operating Temperature -10 to 50 °C
Protection Rating IP52
Dimensions 136 × 245 × 63 mm
Weight 1.2 kg


Applications

Process transmitter calibration, loop troubleshooting, temperature signal simulation, switch checks and documented instrument maintenance.

Configuration And Selection Notes

Pressure modules, pressure generation equipment and full calibration management software licences are configuration items. Measurement and source ranges differ; use the complete specification for accuracy and allowable loads.


Contact us to enquire about the Fluke 754 Documenting Process Calibrator With HART and the configuration or accessories suited to your application.



 Inquiry - Fluke 754 Documenting Process Calibrator-HART